Welcome To Elaf Electric.

Power Cables

are essential for efficient electricity transmission, offering durability, safety, and minimal power loss across various industrial and residential applications.

01.

Wiring Cables

Used in house wiring

• As per BSEN 50525-2-31, BSEN 50525-3-41, BS 6231
• Manufactured in sizes of 1.5 up to 630 mm²
• Rated 450/750V as per BSEN.
• HO7V-R, HO7V-K, HO7V-U types are available with PVC
• HO7Z-R, HO7Z-K, HO7Z-U types are available with XL-LSZH.

 Characteristics:

• Minimum service temperature -15 ℃
• Service temperature 90 ℃ can be offered for XLLSZH and HR PVC
• Manufactured to higher temp. 105º C PVC upon request
• Service temperature 70 ℃ for standard PVC
• Maximum short-circuit temperature 160 ℃ (max.5s) for PVC & 250 ℃ for XL-LSZH Flame non-propagation available.

02.

Flexible Cables

Used in applications requiring flexible cable wiring

• As per BSEN 50525-2-11
• H05VV-F / H05 V2V2-F
• H03VV-F / HO3V2V2-F

 Characteristics:

• Minimum service temperature -15°C
• Service temperature 90°C and 105°C can be offered
• Flame non-propagation available
• Service temperature 70°C for standard
• Maximum short-circuit temperature 160°C (max. 5s)
• Flexible conductor Class 5

03.

Dupan panel Wire

Used in panel wiring

• BS 6231, Type CK
• Circular class 5 flexible copper conductor as per BS EN 60228
• Heat Resistant PVC type TI3 as per BS EN 50363-3
• BS EN / IEC 60332-1
• 600/1000V

 Characteristics:

• Minimum service temperature -15°C
• Service temperature shall be 90°C
• Flexible conductor

04.

Low-voltage power cables

Used in LV distribution application

• As per IEC 60502-1
• From 1KV – 3.3 KV
• Can provide Single Core / Multicore as required
• Can provide lead sheathed cables
• Can provide steel tape/steel wire armor option
• Available with LSZH/PVC/PE sheath option
• RV/N2 XY types are available

 Characteristics:

• Minimum service temperature -15°C
• Maximum short-circuit temperature 250°C (max. 5s)
• Meter by meter marking
• Maximum service temperature 90°C
• Flame non-propagation available

05.

Instrumentation cables

Used to connect electrical instrument circuits & provide communication service in and around process plants

• As per BSEN 50288-7, BS 5308-1, IEC 60092-376, BS 6883, BS 7917
• Up to 1 kV
• Can provide lead sheathed cables
• Available in armored construction
• Available with LSZH sheath option
• Pilot cables as per customer design
• Individual and/or overall screening
• Can provide XLPE insulated cables suitable for 90°C
• Field bus cables are also available
• Can provide fire rated cables as per IEC 60331

 Characteristics:

• Minimum service temperature -15°C
• Service temperature 70°C and 90°C can be offered
• Maximum short-circuit temperature 160°C (max. 5s)

06.

Auxiliary cables

Used in auxiliary & control circuit applications

• As per IEC 60502-1, BS 5467, BS 6724, BS 7846
• Up to 1 kV
• Can provide lead sheathed cables
• Available in armored construction
• Available with LSZH sheath option
• Can provide fire rated cables as per IEC 60331

all Type Off
Electric Cables