Specialized electric cables
Are crucial for electric vehicles, handling high voltage and current, and resisting environmental challenges, ensuring efficient and safe performance.
Fire Resistant cables
01.
FlamBICC 1 cables
Used in fire resistant cable applications
• As per BS8592
• Certified to BS 6387 for small sizes
• Certified to IEC 60331 for larger sizes
• 600/1000V
Characteristics:
• Maximum service temperature 90° C
• Low corrosive gases emission (LSZH)
• Maximum short-circuit temperature 250° C (max. 5s)
• Flame non-propagation
02.
FlamBICC 2a cables
Used in fire resistant cable applications
• As per BS 7629-1
• Certified to BS 6387
• Class PH 60 of BSEN 50200
• 300/500V
Characteristics:
• Maximum service temperature 90°C
• Low corrosive gases emission (LSZH)
• Maximum short-circuit temperature 250°C (max. 5s)
• Flame non-propagation
03.
FlamBICC 2a Enhanced cables
Used in fire resistant cable applications
• BS 7629-1
• Certified to BS 6387
• Class PH 120 of BS EN 50200, BS 8434-2 (120 minutes)
• 300/500V
Characteristics:
• Maximum service temperature 90°C
• Low corrosive gases emission (LSZH)
• Maximum short-circuit temperature 250°C (max. 5s)
• Flame non-propagation
Note: provided with optional green strip
04.
FlamBICC 3 cables
Used in fire resistant cable applications
• Can provide single core / multi core as required
• Certified to BS 6387 for small sizes/ single core
• Certified to IEC 60331 for larger size/ single core
• BS 6387 CWZ and IEC 60331-21 at 950°C/multi core
• 600/1000V
Characteristics:
• Maximum service temperature 90°C
• Low corrosive gases emission (LSZH)
• Maximum short-circuit temperature 250°C (max. 5s)
• Flame non-propagation
05.
FlamBICC 4 cables
Used in fire resistant cable applications
• Power cables meeting BS 7846 F2 & BS 6387 CWZ
• 600/1000V
Characteristics:
• Maximum service temperature 90°C
• Low corrosive gases emission (LSZH)
• Maximum short-circuit temperature 250°C (max. 5s)
• Flame non-propagation
06.
FlamBICC 6 cables
Used in fire resistant cable applications
• Power cables meeting BS 7846 F120, BS 8491 120 minutes, and BS 6387 CWZ
• BS 8519 Category 1, 2 & 3 power applications
• 600/1000V
Characteristics:
• Minimum service temperature 90°C
• Low corrosive gases emission (LSZH)
• Maximum short-circuit temperature 250°C (max. 5s)
• Flame non-propagation
Note: provided with optional orange strip
VFD and VSD
01.
VFD and VSD cables
Used in VFD/VSD Panel System
• Cable complying with IEC 60502-1
• All cables are Flame Retardant to IEC 60332-1 Vertical Flame Propagation Test
• Conductor high conductivity soft annealed copper according to BS EN 60228, Class 1, Class 2 stranded and Class 5 flexible conductor
• Insulation polyvinyl chloride (PVC) & Cross-linked polyethylene (XLPE) with Maximum service temperature 90ºC
Shielding is upon request
• Copper tape screen
• Copper wire screen – cross section
• Tinned copper & annealed copper wire Braided
Characteristics:
• Outer sheathing is PVC ST2 and LS0H ST8
• Three Ph cores can be assembled with three earthing bare conductor or insulated conductor
• Can provide tinned copper conductor
• Can provide high fire performance, Flame propagation tests: IEC 60332-3.24 Category C – IEC 60332-3.23 Category B – IEC 60332-3.22 Category A
• Can provide fire resistant control cable with MICA – BS 6387 CAT CWZ
• Can provide chemical performance Oil resistance
• Can provide sunlight & UV Resistant
• Can provide water resistance
• Can provide anti-termite resistant
• Can provide special color for insulation and outer sheath
• Can provide numbering identification for cores
• Can provide special outer sheath material PVC(FRLS)
THHN / THWN
01.
THHN / THWN
Used where oil resistance is required
• As per UL standard
• 600V
Characteristics:
• Minimum service temperature -15°C
• Maximum short-circuit temperature 160°C (max. 5s)
• 90°C in dry and 75°C in wet location
• Oil resistant
Arctic grade flexible
01.
Arctic grade flexible
Used for every low ambient temperature
• As per BS 6004
• Lowest ambient temperature for operation -40°C for arctic grade cables
• 300/500V
Characteristics:
• Minimum service temperature -40°C
• Flexible conductor, class 5
• Flame non-propagation
• Operating temperature 70°C
• Maximum short-circuit temperature 160°C (max. 5s)
Rubber flexible
01.
Rubber flexible
Used in different applications requiring flexibility
• As per BS EN 50525-2-21, BS EN 50525-2-81, BS EN 50525-2-83, BS EN 50525-3-21, IEC 60092-353, IEC 60092-354, BS 6883, BS 7917
• Available for different harmonized grades (HO7RN-F, HO7BN4-F, HO5BN4-F, etc) Arc welding cables
Characteristics:
• Minimum service temperature -40°C
• Flexible conductor, class 5/6
• Service temperature 90°C
• Maximum short-circuit temperature: 250°C (max. 5s)
PetroBICC
PetroBICC
Used in oil, gas and petro chemical industries
• Available in LV/MV Power, LV control/ auxiliary and instrumentation cables
Characteristics:
• Minimum service temperature -15°C
• Maximum short-circuit temperature: 250°C (max. 5s)
• Service temperature 90°C for cables with XLPE insulation
• Oil/hydrocarbon resistant
01.
MarineBICC
01.
MarineBICC
For ship wiring applications
• As per IEC 60092 standard
• Available for power, control, instrumentation, and shipboard applications
• Available in fire-resistant design also
• 600/1000V for LV
• 150/250V for instrumentation cables
Characteristics:
• Minimum service temperature -15°C
• Maximum short-circuit temperature 250°C (max. 5s)
• Service temperature 90°C
• LSZH property