Power Cables
are essential for efficient electricity transmission, offering durability, safety, and minimal power loss across various industrial and residential applications.
01.
Wiring Cables
Used in house wiring
• As per BSEN 50525-2-31, BSEN 50525-3-41, BS 6231
• Manufactured in sizes of 1.5 up to 630 mm²
• Rated 450/750V as per BSEN.
• HO7V-R, HO7V-K, HO7V-U types are available with PVC
• HO7Z-R, HO7Z-K, HO7Z-U types are available with XL-LSZH.
Characteristics:
• Minimum service temperature -15 ℃
• Service temperature 90 ℃ can be offered for XLLSZH and HR PVC
• Manufactured to higher temp. 105º C PVC upon request
• Service temperature 70 ℃ for standard PVC
• Maximum short-circuit temperature 160 ℃ (max.5s) for PVC & 250 ℃ for XL-LSZH Flame non-propagation available.
02.
Flexible Cables
Used in applications requiring flexible cable wiring
• As per BSEN 50525-2-11
• H05VV-F / H05 V2V2-F
• H03VV-F / HO3V2V2-F
Characteristics:
• Minimum service temperature -15°C
• Service temperature 90°C and 105°C can be offered
• Flame non-propagation available
• Service temperature 70°C for standard
• Maximum short-circuit temperature 160°C (max. 5s)
• Flexible conductor Class 5
03.
Dupan panel Wire
Used in panel wiring
• BS 6231, Type CK
• Circular class 5 flexible copper conductor as per BS EN 60228
• Heat Resistant PVC type TI3 as per BS EN 50363-3
• BS EN / IEC 60332-1
• 600/1000V
Characteristics:
• Minimum service temperature -15°C
• Service temperature shall be 90°C
• Flexible conductor
04.
Low-voltage power cables
Used in LV distribution application
• As per IEC 60502-1
• From 1KV – 3.3 KV
• Can provide Single Core / Multicore as required
• Can provide lead sheathed cables
• Can provide steel tape/steel wire armor option
• Available with LSZH/PVC/PE sheath option
• RV/N2 XY types are available
Characteristics:
• Minimum service temperature -15°C
• Maximum short-circuit temperature 250°C (max. 5s)
• Meter by meter marking
• Maximum service temperature 90°C
• Flame non-propagation available
05.
Instrumentation cables
Used to connect electrical instrument circuits & provide communication service in and around process plants
• As per BSEN 50288-7, BS 5308-1, IEC 60092-376, BS 6883, BS 7917
• Up to 1 kV
• Can provide lead sheathed cables
• Available in armored construction
• Available with LSZH sheath option
• Pilot cables as per customer design
• Individual and/or overall screening
• Can provide XLPE insulated cables suitable for 90°C
• Field bus cables are also available
• Can provide fire rated cables as per IEC 60331
Characteristics:
• Minimum service temperature -15°C
• Service temperature 70°C and 90°C can be offered
• Maximum short-circuit temperature 160°C (max. 5s)
06.
Auxiliary cables
Used in auxiliary & control circuit applications
• As per IEC 60502-1, BS 5467, BS 6724, BS 7846
• Up to 1 kV
• Can provide lead sheathed cables
• Available in armored construction
• Available with LSZH sheath option
• Can provide fire rated cables as per IEC 60331